Taylor Plumbing Whangarei logo

Radiators & Boilers

Air to Water Heat Pumps in Whangarei

Warm floors or radiators, with no gas bill, no flue and no bottles to swap. The unit lives outside the house and warms the water in your heating pipes, and often your hot water too. We plan, install and service them across Whangarei and Northland, in new builds and in place of old boilers.

Our in house certifying plumber runs the water side, our electrician wires it, and we bring in the licensed refrigeration tech, so you deal with one firm. Heating packed up mid winter? We answer 24/7.

  • Master Plumbers member logo

    Master Plumbers Member

  • Site Safe member logo

    Site Safe Member

  • Certifying Plumber, Certifying Gasfitter and Certifying Drainlayer

    Certifying Plumber, Gasfitter and Drainlayer

  • Google logo

    Google Rated 4.9

Get help with air to water heat pumps

Forms are picked up 24/7, nights and weekends too. Urgent? Call 09 885 5973.

We'll use your details to respond to your enquiry. Marketing messages are optional. Privacy Policy

Overview & Answer

Is an air to water heat pump a good choice for a Whangarei home?

Usually, if you want radiators or underfloor heating without gas. The unit outside pulls heat from the air and puts it into water that runs through your floor loops or radiators, and often your hot water cylinder as well. There is no fuel to buy and no flue, and our mild winters are easy work for it.

Hissing, leaking or tripping? Do this first

  1. Hissing or a strange smell at the outdoor unit

    Some units use R290, a refrigerant that can burn, and makers warn that leaked refrigerant meeting a flame gives off poisonous gas. Switch off at the board if safe, keep flames and grinders clear, and ring 111 for fire or smoke.

  2. Water around the cylinder or indoor unit

    Only touch a dry switch, otherwise cut power at the board. Stay away from anything spraying out of the relief pipe.

  3. Breaker trips every time

    Leave that circuit off rather than resetting it again and again. Write down any code on the controller for us.

  4. House gone cold, nothing leaking

    Check the controller has power and the right schedule. Jot down the gauge pressure and any code. Refilling is our job.

Call 09 885 5973

Scope & Inclusions

  • Monobloc units piped straight into the heating
  • Split units with a hydrobox or cylinder inside
  • Underfloor loops, radiators and fan coils
  • Heating and hot water from one unit
  • Gas, LPG and diesel boilers swapped for a heat pump
  • Room by room heat loss and unit sizing

Need something else?

Timing & Suitability

When an air to water heat pump makes sense

  • The boiler is on borrowed time

    Your floor loops and radiators can stay. Only the thing that heats the water changes.

  • No gas at the gate

    Out of town there is no piped gas, and swapping LPG bottles all winter gets old fast.

  • A slab about to be poured

    Floor loops and a heat pump planned together give the lowest water temperatures and the best results.

  • The cylinder is due as well

    One outdoor unit can take over both jobs, so you replace two things with one.

Systems & Types

Monobloc, split or packaged cylinder

The main difference is where the refrigerant stops and the water starts.

  • Monobloc

    All the refrigerant stays sealed inside the outdoor box. Makers describe a packaged unit as needing only water and electric connections, so we pipe it straight into the heating and our electrician wires it.

  • Split with a hydrobox

    Refrigerant pipe runs from the outdoor unit to a box inside, where its heat passes into the water. Joining that refrigerant pipe is a job for a licensed refrigeration technician, booked as part of your install.

  • Packaged cylinder

    The hot water cylinder, pump and controls come as one indoor unit fed by the outdoor unit. These cylinder units come in sizes such as 170, 200 and 300 litres.

  • Keep your cylinder

    A hydrobox can heat a cylinder you already have, but only one built for a heat pump, with a coil inside. A standard element cylinder will not do.

Proof & Promise

Why choose Taylor for air to water?

  • Certifying plumber and gasfitter in house

    Our certifying plumber and gasfitter are on staff, and one of them signs off every job. 35 years in the trade and Master Plumbers membership, so home work carries the Master Plumbers Guarantee: 12 months, up to $20,000 incl GST. Our heating labour carries a lifetime guarantee, and parts keep the maker's warranty.

  • Sized from your house

    We work out what every room loses on a cold night before we pick a unit, so it is neither straining nor short cycling.

  • The refrigeration tech sorted

    On split units a licensed refrigeration technician makes the refrigerant joints. We book them, brief them and keep their part on our quote.

  • Boiler out, heat pump in

    Our gasfitter caps the gas and we take the old boiler away in the same job.

  • Set up for the coast

    Outdoor units sited out of the worst spray, on a solid base, with room to service and the maker's coastal advice followed.

  • 24/7 when the heat goes

    When the house goes cold in the middle of winter, a real person picks up, day or night.

Principles & Efficiency

Cooler water, longer running

A heat pump makes the most heat for the least power when the water it sends round is only warm, not hot. A packaged indoor unit can run anywhere from 25 to 60°C, for example 40°C water for radiators and 30°C for underfloor, as two zones off one unit.

That is why floors are the easiest match: a slab gives off heat across its whole area, so lukewarm water does the job. Radiators work too, if each is big enough for its room at the lower temperature.

Most units carry an electric booster element, which makers say covers any shortfall in heating capacity. A well sized unit rarely needs it, since it costs more to run.

Space & Water

One unit for the heating and the cylinder

Many units also heat a cylinder through a coil inside it, on top of the space heating. That saves a second outdoor unit. We size the cylinder for your busiest hour and set the hot water schedule so it does not clash with the heating on frosty mornings.

Roles & Trades

Plumbing, refrigeration and wiring on one job

The pipes, buffer, cylinder, valves and controls are plumbing, done by us and certified by our certifying plumber. The power supply is electrical work, and EECA says heat pumps need a licensed electrician.

Refrigerant is its own licensed trade. The government careers service says heat pump technicians must be registered and hold an electrical service technician practising licence plus a refrigerant handling licence. A monobloc has nothing to join; on a split, the licensed technician we bring in makes those joints to our programme.

Check the warranty terms too. Some makers tie their five year cover to a factory trained installer fitting and commissioning the unit, so we show you who commissions yours before you sign.

Sizing & Capacity

Sized from heat loss, room by room

A single range can run from about 5 kW to 23 kW, so guessing is a gamble. We measure every room, look at insulation, windows and floors, and calculate the heat each one leaks away in July.

Too small and the booster element ends up doing heat pump work at plain electric rates. Too big and the unit starts and stops in short bursts, which heat pump makers say costs efficiency. The heat loss figure also tells us which radiators need upsizing.

Siting & Noise

Where the outdoor unit sits

A 6 kW packaged unit can weigh close to 100 kg empty, and manuals ask for a level spot that can carry its weight and vibration. We set it on a concrete pad or solid bracket, with free air around it, service room and a drain for defrost water.

Packaged units are rated around 45 dBA at one metre. Manuals say to choose a spot where the noise does not bother the neighbours, and Whangarei's District Plan sets tighter limits from 10pm to 7am. In Christchurch a council ordered one family's heat pump off overnight after complaints, so we keep units away from bedroom windows on both sides of the fence.

Salt & Corrosion

Living near the sea

Manuals warn that a unit exposed to briny air can lose a lot of performance and suffer damage inside. EECA's installer guidance for hot water heat pumps says the same kind of outdoor coil and pipework needs protecting at coastal sites.

On the coast we put the unit on the sheltered side of the house, out of direct spray, and use coil protection where the maker allows it. A yearly clean of the outdoor coil, which makers ask for anyway, matters even more by the beach.

Switching & Conversion

Moving from a boiler to a heat pump

Old system water is full of sludge, and makers' manuals warn that poor water quality can lead to breakdowns and leaks. We flush, refill and treat before the heat pump runs, and the unit gets its own supply from the switchboard.

Was the boiler your only gas appliance? Then end the gas supply, because the Gas Industry Company says the daily fixed charge only stops when supply does.

Process & Steps

Four steps to a warm house

  1. 01

    Your house and heating now

    Floor loops, radiators or new build plans, what heats the house and water now, and a photo of any boiler.

  2. 02

    Site visit and heat loss

    We measure up, pick the outdoor spot, check the switchboard and system water, and work out the heat needed.

  3. 03

    Options on one quote

    Monobloc or split, unit size, cylinder, radiator changes, electrical and refrigeration work, each as its own line with GST shown.

  4. 04

    Install and commission

    We fit, flush, fill and test, set the flow temperatures and zones, walk you through the controller and hand over the paperwork.

Costs & Quotes

How an air to water heat pump is priced

Swapping a heat pump onto existing floor loops and heating a new house from scratch are worlds apart, so we price each system in writing after the site visit.

The quote covers the outdoor unit, any hydrobox or cylinder, buffer tank and pumps, pipework and valves, controls, the electrical supply, refrigeration work on split units, removal of an old boiler, flushing and treatment, commissioning, certificates and travel, with GST shown.

What changes the total: the unit size, monobloc or split, how far the unit sits from the plant, radiator upgrades, switchboard work, gas capping and coastal protection. If we open things up and find more work, you hear about it and approve it in writing first.

Request a quote

Whangarei & Northland

Air to water heat pumps around Whangarei

Natural gas pipes cover just some Whangarei streets, so an air to water unit is often the simplest way to run floor heating or radiators up here. NIWA puts the city's average July overnight low near 8°C.

Inland at Glenbervie, Maungatapere and Kaikohe it gets colder, and the sizing allows for that. We cover all of Northland from Whangarei: Mangawhai, Dargaville, the Bay of Islands, Kerikeri and Kaitaia. Travel beyond Whangarei is quoted before we book. Kaipara and Far North council rules differ, and we work to them.

EECA on heat pumps

Customers & Properties

Owners, builders and landlords

  • Homeowners with a tired boiler

    A heat pump priced against a new boiler on the same pipes.

  • New builds and owner builders

    Unit, cylinder and loops planned from the drawings, with power and the pad ready before cladding.

  • Landlords

    Tenancy Services accepts central heating for the heating standard only if it warms the lounge itself with enough output. We check that first.

  • Rural and lifestyle blocks

    No gas main, fuel truck or tank to fill. Power is the only supply needed.

Related & Similar

Other heating pages

More on the parts of a heating system and on hot water.

View all heating services

Questions & Answers

Questions about air to water

How much does an air to water heat pump cost in NZ?

We quote it in writing after one visit, because the house and the pipes already in it set the price. Fitting a unit to floor loops that already work is the smaller job. A whole new system, a split with long refrigerant runs, radiator upgrades or switchboard work push it up. Each part has its own line on the quote, GST shown.

What does an air to water heat pump cost to run?

Less than gas, going by EECA, which calls heat pumps the lowest cost home heating at about one third of what gas heating costs. EECA also puts typical yearly savings at $122 against piped gas and $352 against bottled LPG, not counting the daily gas charge.

Can one heat pump run underfloor heating and radiators together?

Yes. The floor and the radiators each get their own zone and water temperature. Some controllers, for example, can run two flow temperatures at once, such as 40°C to the radiators and 30°C to the floor. We size both circuits so the unit is not forced to run hotter than it needs.

What is the difference between a monobloc and a split air to water heat pump?

A monobloc keeps all its refrigerant inside the outdoor unit and sends heated water into the house. A split runs refrigerant pipe inside to a hydrobox or cylinder unit, where the water is heated. Monoblocs need only plumbing and power on site; splits also need a licensed refrigeration technician to connect them.

Who can install an air to water heat pump?

Up to three licensed trades: a plumber for the pipes and cylinder, an electrician for the power, and on a split, a refrigeration technician. We run all three on one quote.

How big a unit does my house need?

Big enough to cover the heat your home loses on its coldest nights, calculated one room at a time. Square metres tell you little on their own, since insulation, windows, ceiling height and which rooms you heat all shift the number. Two houses of the same size can need quite different units.

Do air to water heat pumps work in a Northland winter?

Yes, comfortably. NIWA records Whangarei's average July night at about 8°C, and a 6 kW packaged unit can be rated down to minus 20°C. When a damp, still morning frosts the coil, the unit runs a short defrost before carrying on. A heated floor holds its warmth through the pause.

Can an air to water heat pump heat my hot water as well?

Yes, most can. The unit heats a cylinder through a coil, either a packaged cylinder made for it or an existing cylinder that has the right coil. A plain element cylinder cannot be used. If you only want hot water, a dedicated hot water heat pump is simpler.

What happens to my pipes when a heat pump replaces my boiler?

Most of them stay. Floor loops, the manifold and radiator pipes are reused, though radiators sized for hot boiler water get checked against each room and a few may need upsizing. Only the boiler and flue come out.

Do I need building consent for an air to water heat pump?

For the heating side, usually not. Hot water differs: MBIE says a new or extra heat pump water heater needs consent, while a same spot replacement by a certifying plumber can be exempt. Before work starts, we confirm the position for your job with Whangarei District Council.

How noisy is an air to water heat pump?

Quieter than most people expect, but not silent. Packaged units are quoted around 45 dBA at one metre, but hard walls and corners bounce sound back. Placement does most of the work, and a quiet night mode helps where the unit has to sit near a bedroom.

Will salt air damage an air to water heat pump?

Yes, if the unit faces the spray. That is why we site coastal units with care and check each maker's warranty for coastal conditions before you choose a model.

Can an air to water heat pump cool the house in summer?

Yes, on models built for it. Several of the major ranges offer cooling, and some monoblocs both heat and cool. Whether cooling suits your floor or radiators depends on how the system is built, so we settle it at design stage.

Is there a grant for air to water heat pumps?

Not from the government. Warmer Kiwi Homes only funds high wall heat pumps, and a home with working central heating in a living area misses out on its heater grant. A few banks lend for energy upgrades on special terms, so ask yours what is on offer now.

Does an air to water heat pump need servicing?

Yes, once a year. Makers' manuals call for yearly maintenance, including the outdoor coil and the strainer in the water pipe, since a blocked strainer cuts the flow. We also check pressure, the expansion vessel, valves and controls.

Get your air to water heat pump priced

Tell us what heats the house now and send a photo of any boiler. We come back with a unit size, the options and a written price.

Get help with air to water heat pumps

Forms are picked up 24/7, nights and weekends too. Urgent? Call 09 885 5973.

We'll use your details to respond to your enquiry. Marketing messages are optional. Privacy Policy