Taylor Plumbing Whangarei logo

Fires & Heaters

Wetback Installation and Repairs in Whangarei

Your wood burner can heat the water as well as the lounge. Or maybe the wetback you have is banging, steaming or barely warm. Taylor Plumbing installs, repairs, replaces and removes wetbacks across Whangarei and Northland, on low pressure and mains pressure cylinders.

Our certifying plumber does the copper, the vent, the valves and the consent. Wetback boiling in the middle of the night? We answer 24/7.

  • Master Plumbers member logo

    Master Plumbers Member

  • Site Safe member logo

    Site Safe Member

  • Certifying Plumber, Certifying Gasfitter and Certifying Drainlayer

    Certifying Plumber, Gasfitter and Drainlayer

  • Google logo

    Google Rated 4.9

Get help with wetbacks

Forms are picked up 24/7, nights and weekends too. Urgent? Call 09 885 5973.

We'll use your details to respond to your enquiry. Marketing messages are optional. Privacy Policy

Overview & Answer

Can I get a wetback fitted in Whangarei?

Yes, if your burner is built to take a water jacket and the cylinder can sit close to the fire. Our certifying plumber runs copper from the jacket to a vented cylinder, fits a tempering valve and gets the building consent. It pays off best when the fire burns every day through winter.

Hot water rises out of the jacket into the cylinder while cooler water sinks back to the fire, so most wetbacks need no pump. When the fire sits cold, including all summer, the element takes over.

Wetback banging, boiling or out of water? Do this first

  1. Banging, rumbling or steam

    Put no more wood on and let the fire burn down. Leave the water on, because the jacket needs water through it while there is any heat in the firebox. Keep clear of the roof vent and any relief valve outlet, then ring us.

  2. Water off or pump down

    Do not light the fire while the mains are off, the header tank is empty or a power cut has stopped your tank pump. A dry jacket can flash to steam.

  3. Leak at the fire or cylinder

    Let the fire go right out before anyone shuts a valve. After a leak, leave it unlit until a plumber has refilled and checked the system. Stay away from the cylinder's wiring if water is near it.

  4. Someone burnt or the fire spreading

    Get everyone outside and call 111.

Call 09 885 5973

Scope & Inclusions

  • New wetbacks on wood burners
  • Low pressure and mains pressure wetback cylinders
  • Pumped wetback systems
  • Kettling, boiling and banging
  • Vent pipes, relief and expansion valves
  • Wetback removal and capping

Need something close to this?

Signs & Symptoms

When a wetback needs a plumber

Ring us if any of these sound familiar.

  • Rumbling or knocking with the fire going

    Water is boiling in hot spots. Scale inside the jacket, or a pipe that does not climb enough on its way to the cylinder, is the usual cause.

  • Steam or water out of the roof vent

    An open vented cylinder dumps heat this way when it runs too hot. Once in a while is fine. Every time you light the fire is not.

  • Relief valve running

    On mains pressure coil cylinders these valves open more often than on plain electric ones and wear out sooner. Nonstop running means a valve or setting needs looking at.

  • Roaring fire, lukewarm water

    The water is not circulating. Air in the loop, a sagging run, pipe that is too small or a cylinder too far away will all do it.

  • Water around the hearth or cylinder

    A jacket, joint or cylinder is leaking. Keep the fire out until it is repaired.

  • Taps running scalding hot

    A fire has no thermostat, so the tempering valve is the only thing holding the bathroom down to a safe heat.

Cylinders & Setups

Three ways to plumb a wetback

The fire side stays vented to open air in every one. What changes is how the heat gets to your taps.

  • Low pressure, open vented

    The simplest and cheapest: a copper cylinder fed from a header tank, with an open pipe through the roof in place of pressure valves. Nothing to pump or wear out. Showers are gentler, and the cylinder has to sit near the fire and higher than it.

  • Mains pressure, thermosiphon coil

    The usual choice for a new install. Fire water rises through a coil inside a stainless cylinder and hands its heat to mains pressure water, so showers stay strong without a pump. Its relief and expansion valves get a workout and need changing more often.

  • Mains pressure, pumped coil

    A high temperature pump drives fire water to the coil, so the cylinder can go where it fits instead of right beside the fire. You gain some control over the heat and take on a pump to maintain.

Proof & Promise

Why Northland rings Taylor about wetbacks

  • Certifying plumber in house

    Level says a wetback must be done by a certifying plumber, or someone working under one. Ours signs the work off. 35 years in the trade, and the Master Plumbers Guarantee on home work: 12 months, up to $20,000 incl GST. A lifetime guarantee on our heating labour, with parts under the maker's warranty.

  • All three setups

    Low pressure, thermosiphon coil or pumped, on any burner built to take a jacket. We choose what suits the house, not whatever is on the shelf.

  • Consent done for you

    Plumbing schematic, cylinder position, producer statement and the inspection booking go to council together with the burner details.

  • Tempering that keeps your flow

    We match the valve to your water pressure, so a low pressure shower does not drop to a dribble once the wetback is tempered.

  • A real person 24/7

    Cylinder thumping or the vent pouring steam late at night? Ring any hour and talk to someone who knows wetbacks.

  • A written price first

    Jacket, cylinder, copper, vent, valves, consent, electrician and GST set out before work starts. Extras wait for your yes.

Heat & Circulation

Fire, water and a copper loop

A wetback is a water jacket at the back or side of the firebox, joined to the cylinder by two copper pipes. Hot water climbs the flow pipe, cooler water drops down the return, and that loop keeps turning while the fire burns.

It only works if the pipes rise steadily with no dips. BRANZ Level recommends 25 mm copper, and burner manuals want the return to rise at least 1 in 12. Pulse valves or a pump let the cylinder sit further off.

Jackets put roughly 1.5 to 4 kW into the water. That heat comes out of the room, so the lounge runs a little cooler.

Safety & Pressure

Why wetbacks boil and bang

Nothing turns a fire down when the cylinder is full of hot water. That is why the wetback side must be vented to open air, and why MBIE says a wetback cannot be connected directly to a mains pressure supply.

Kettling is water flashing to steam in a hot spot. Scale and poor flow cause it: lime coats the jacket, or a sagging pipe stalls the loop. Level says wetbacks do not suit water very high in lime.

In 2012 a Papamoa wetback heater exploded after its water was turned off for a leak and never drained. Steam, banging or a leak is a reason to let the fire die, never to shut the water off with the fire still going.

Rules & Approvals

Consent, clean air and tempering

Plan on a building consent for any new wetback, including one added to a burner you already have. District councils issue consents for heating appliances, and they want a plumbing schematic and the cylinder position along with the burner details.

On a section under 2 ha, the burner has to be on the Ministry for the Environment's authorised list, and models with a wetback are no exception. A jacket cools the fire and lifts its emissions, so the burner must pass with the jacket fitted.

Fire heated water has to be tempered before it reaches a bathroom tap. Choose the wrong valve on a low pressure system and the shower can fade to a trickle: in a 2018 Masterton case, MBIE ruled a wetback job failed the Building Code at 1.4 litres a minute.

Retrofits & Removals

Adding, swapping or taking one out

Not every burner takes a jacket, and fitting one the maker never approved can void the burner's emissions approval. We check the model before anything else. If it cannot take one, the choice is a new burner or no wetback.

A worn out wetback cylinder can be replaced without consent when the new one is a comparable open vented cylinder, in the same spot, on the same pipework. That comes from Schedule 1 of the Building Act. Moving it, new pipe runs or a switch to mains pressure means consent first.

Taking the fire out? We drain the loop, cut and cap the copper, and leave the cylinder heating on its element. If it is old, that is the time to talk about a mains pressure or heat pump cylinder.

Value & Payback

Who a wetback pays off for

Consumer NZ puts it plainly: if the fire is not lit every day, a wetback is unlikely to earn its keep. It suits:

  • Rural homes and lifestyle blocks with their own firewood
  • People home most of the day, like retirees and farmers
  • New builds and big renovations, where the cylinder can go right beside the fire
  • Homes with solar hot water to carry the summer months

Fire only on weekends, or the cylinder at the far end of the house? A heat pump water heater may be the better spend, and we will say so.

Process & Steps

From first call to hot water off the fire

  1. 01

    Tell us about the fire

    Burner make and model, where the cylinder sits and how strong your showers are. Photos help.

  2. 02

    Site check

    We confirm the burner takes a jacket, measure the pipe route and vent, and look at your water supply.

  3. 03

    Quote and consent

    A written price, then we draw the plumbing schematic and lodge the consent with the burner details.

  4. 04

    Install, fill and test

    Loop, vent, valves and tempering in, the system filled and run with a fire lit, then inspection and paperwork.

Costs & Quotes

How wetback work is priced

Repairs and valve work go on time and parts, and we explain how that adds up before we head out. New installs, cylinder swaps and removals get a fixed written quote once we have seen the fire and the cylinder.

What moves it: the burner, jacket size, cylinder type and size, pipe length and height, roof vent, valves, consent and inspection fees, any electrician, travel and GST.

Request a quote

Whangarei & Northland

Wetbacks right across the north

Based in Whangarei, we cover all of Northland, from Kaitaia, Kerikeri and the Bay of Islands to Dargaville and Mangawhai, and travel beyond the Whangarei district is quoted first.

Your wetback consent goes to Whangarei, Kaipara or Far North District Council, depending on the address. Kaipara's solid fuel form asks for a plumbing schematic of the wetback and the cylinder's location.

Northland Regional Council treats burning for heating as permitted, provided your smoke does not become a nuisance beyond your boundary. Blocks of 2 ha or more can have a burner that is not on the authorised list, and wood cooking stoves, some still made in Whangarei with wetbacks, sit outside the national burner rules.

NRC chimney smoke rules

Customers & Properties

Who calls us about wetbacks

  • Rural homes and lifestyle blocks

    Firewood on hand, tank or bore water and the burner going all winter.

  • Baches and holiday homes

    Fire on when you are up, element the rest of the time. We check the loop before winter.

  • Builders and renovators

    Burner and cylinder placed together at the design stage, before linings go up.

  • Landlords and property managers

    Wetback cylinders, valves and tempering kept in order.

Related & Similar

Related services

Other work on the same fire or cylinder.

View all heating services

Questions & Answers

Wetback questions

How much does it cost to install a wetback?

We quote after seeing your fire, cylinder and house. A burner that already takes a jacket, with the cylinder just behind the wall, is the easy end. A new burner, a new mains pressure cylinder or a long pipe run is the dear end. Consumer NZ calls wetbacks expensive to install.

Will a wetback lower my power bill?

Yes, through winter, if the fire runs every day. The saving stops when the fire does, so the cylinder still needs its element for summer. Consumer NZ says the sums work best for people home most of the day, not households out at work.

Can I have mains pressure hot water with a wetback?

Yes. The wetback itself must stay vented, so it cannot connect straight to the mains, but it can heat a coil inside a mains pressure cylinder. The catch is relief and expansion valves that work harder and need replacing more often than on a plain electric cylinder.

Why does my wetback bang or rumble?

That is kettling, water flashing to steam in hot spots. Usual causes are lime or scale inside the jacket, a pipe that dips or climbs too little, air in the loop, or a cylinder already at full heat. Let the fire burn down and get it checked, because the noise means the system is running too hot.

Is it dangerous if my wetback boils?

Yes, if the vent is blocked or the jacket runs dry. A vented system lets steam escape up the roof pipe, but a blocked vent, a dry jacket or water trapped behind a closed valve can build pressure fast. Stop feeding the fire, leave the water on and call us. Regular boiling also cooks the cylinder, and MBIE warns high temperatures can damage them.

Can I use the fire when the water is turned off?

No. Burner makers say water must always be available to the wetback while the fire is going. Mains off for repairs, an empty header tank or a tank pump stopped by a power cut all count. Leave the fire unlit until the water is back on and the cylinder has refilled.

Does a wetback need a building consent?

Yes. BRANZ Level says a building consent is needed to install a wetback, and adding one to an existing burner is still an install. In Whangarei it goes through the district council with the burner details, a plumbing schematic and the cylinder position. We put the application together and book the inspection.

Can a wetback be added to my existing wood burner?

Only if the burner was designed for one. Makers sell jackets for certain models, and fitting anything else can void the emissions approval. On a section under 2 ha the burner must stay compliant with the jacket in, and some do not. Send us the make and model and we check before you spend a cent.

Can I replace a wetback cylinder without consent?

Yes, when the new one is a comparable open vented cylinder fixed in the same place on the same pipework. Schedule 1 of the Building Act exempts that swap. Moving the cylinder, new pipe runs or a change to a mains pressure coil cylinder fall outside it, so consent comes first. We check which applies before we quote.

Do I need a tempering valve with a wetback?

Yes, for bathroom taps. Fire heated water has no thermostat, and the Building Code does not allow untempered water from an uncontrolled heat source like a wetback to reach them. BRANZ calls tempering every tap on a wetback system good practice. We fit a tempering valve rated for the heat and suited to your pressure.

Can you take a wetback out when the fire goes?

Yes. We drain the loop, take out or cap the copper at the cylinder and the vent, and make sure the cylinder heats properly on its element alone. If it is an old low pressure cylinder, swapping it for mains pressure or a heat pump at the same visit saves a second call out.

Will a wetback work on tank water?

Yes, with the right setup. A tank below the house feeding it by pump leaves the wetback short of water whenever the pump stops. A header tank in the roof, or a different wetback type, gets around that. Have hard bore water tested first, since Level says wetbacks do not suit water very high in lime.

How close must the cylinder be to the fire?

As close as you can get it, and higher than the fire for any system without a pump. The further the hot water travels, the more heat it loses on the way. If the cylinder has to sit across the house, a pumped coil cylinder or pulse valves can make it work.

Can my wood burner heat other rooms as well?

Yes, with a heat transfer kit. A fan unit high on the lounge wall, or a ducted kit through the ceiling space, moves spare warmth into hallways and bedrooms. Level says ducted units run 40 to 120 watt fans, and some only switch on above a set temperature.

Do you come out after hours for wetback problems?

Yes. A person answers 24/7, and a boiling or leaking wetback goes to the front of the queue. Follow the safety steps on this page first, then ring us and tell us what you can hear and see.

Want hot water from your fire?

Send us the burner model and where the cylinder sits. We will tell you what fits.

Get help with wetbacks

Forms are picked up 24/7, nights and weekends too. Urgent? Call 09 885 5973.

We'll use your details to respond to your enquiry. Marketing messages are optional. Privacy Policy

Get my quoteGet a quote