Pressure & Pumps
Water Pump Repairs and Replacement in Whangarei
We repair and replace house pumps on tank, bore and town water right across Whangarei. A full tank and nothing at the taps, or a pump clicking on and off all night, are the two calls we get most.
When a pump needs to go back to the bench, a loan unit goes in its place and the house stays on water. Pump wiring is done by our in house electrician on the same job, so you deal with one team. We also run 24/7 call outs when you are out of water. An arrival time given before we set off, from a team with 35 years in the trade.
Get help with water pumps

Master Plumbers Member

Site Safe Member

Certifying Plumber, Gasfitter and Drainlayer
Google Rated 4.9
Get help with water pumps
Overview & Answer
Why has my water pump stopped working?
A house pump usually quits for one of five reasons: no power reaching it, an empty tank or a dropped bore, a blocked strainer on the suction side, lost prime, or a worn out motor or controller. Check the power and the water level first. The rest needs someone who can test the pump safely.
A pump is only one part of the setup. The vessel, pressure switch or controller, suction pipe, foot valve, filters and the power supply can all stop the water, so we test each before deciding anything needs replacing.
Pump trouble? Do this first
Sparking, smoking or wet
Stay away from the pump and any water around it. Do not touch the switch or the cable. Call 111 for a fire or an electric shock.
Power off at the house
Ring the lines company before an electrician. Northpower: 0800 10 40 40. Far North, Top Energy: 0800 867 363. Both answer any time.
Pump running, no water
If the switch is dry and safe to reach, turn the pump off so it does not run dry and cook itself. Then check the tank level.
Leave the covers on
Do not open the motor, controller or pressure switch. They carry mains voltage even when the pump is quiet.
Scope & Inclusions
- Tank pump repairs and replacement
- Submersible bore pumps and controls
- Pressure vessels and air charge checks
- Pressure switches and flow controllers
- Pumps that cycle or will not stop
- Lost prime and suction leaks
- Pump failures after outages and surges
- Loan pumps while yours is away
- Pump wiring booked with the job
- Town water boosters with a break tank
- Pumps moved or raised out of flood reach
- Tank strainer and bore intake servicing
Need a different page?
Town water and the taps are just weak?
Low Water PressureNeed a new tank or gutter feed?
Rainwater HarvestingTank or bore plus a council connection?
Backflow Testing & PreventionSewage or stormwater pump alarm?
Pump Stations
Faults & Symptoms
What your pump is telling you
Most pumps give plenty of warning before they die. These are the ones we hear about most.
Clicks on every time a tap opens
Even for a glass of water. The vessel has usually lost its air cushion.
Starts by itself at night
Water is escaping somewhere: a dripping tap, a toilet cistern that keeps topping up, or a leaking pipe or valve.
Runs and runs
It cannot reach its cut out pressure. Think worn pump, a big leak, low water or a failed switch.
Hums but nothing comes out
Lost prime, air getting into the suction line, or the tank or bore has run low.
Will not start at all
No power, low voltage, a thermal cut out after overheating, or a jammed impeller.
Spits and surges at the tap
Air in the line, a waterlogged vessel or a tired switch.
Pumps & Setups
Which kind of pump system have you got?
Check the label and what sits beside the pump. It tells us what parts to bring.
Pump with a pressure tank
A surface pump plus a round vessel and a pressure switch. The most common setup on Northland rain tanks.
Pump with a flow controller
A small box on the outlet starts the pump when a tap opens. No big vessel, but the controller is often the part that fails.
Variable speed pump
Speeds up and slows down to hold an even pressure. Quiet and steady, with electronics that do not love power surges.
Submersible bore pump
Down the bore, usually feeding a tank or pressure system at the top. We fit and service the pump and controls; a driller and Northland Regional Council handle new bores and water take consents.
Booster on town water
A pump drawing from a break tank to lift council supply pressure. Strict rules apply, covered below.
Tank with town water backup
A changeover unit runs the house off rainwater and switches to the council supply when the tank gets low. We set these up with the backflow protection WDC asks for.
Backflow Testing & Prevention
Vessels & Cycling
Why pumps start cycling
Inside the vessel a rubber bladder sits against a pocket of air. That air should be set a little below the pump's cut in pressure, around 15 kPa under, or whatever the pump's manual says, and it can only be checked with the power off and the water pressure let out.
Once the air leaks away, the pump starts and stops with every tap. Each start wears the motor and switch, so a cycling pump left alone becomes a dead pump. We set the charge, find any leak behind it, and replace the vessel if the bladder has split.
Boosting & Supply
Pumps on a council supply
WDC's bylaw keeps equipment that can push pressure surges back up the service pipe off a direct connection unless the council specially approves it, and it bans any direct cross connection to a storage tank.
So the normal build is a break tank topped up through an air gap, a pump drawing from that tank, and the testable boundary device WDC asks for on homes with a second supply. In Kaipara the bylaw rules out any direct pump connection at all.
Placement & Clearances
Floods, heat and noise
A lot of Northland pumps live in a hollow, under the deck or right beside a stream. We can raise the pump on a plinth or move it, mount the controller up high, and give it a vented cover so it does not overheat and trip its cut out.
If the pump is humming under a bedroom window, we look at shifting it or swapping to a quieter model. Long runs down the section are worth sizing properly at the same time.
Servicing & Upkeep
Looking after a tank or bore supply
A choked tank strainer, or a bore screen nobody has looked at in years, is a common reason a house runs dry. A service visit covers the strainer, filters, vessel charge, non return valve and switch, which also keeps the hot water cylinder protected from backflow off the pump.
A tank or bore serving just your own home does not need registering with Taumata Arowai, the drinking water regulator. Looking after it is still on you.
Proof & Promise
Why call Taylor about your pump?
A loan pump keeps you going
Yours goes away for repair, ours goes in, and the taps keep running.
24/7 for a dry house
Out of water at midnight or on a long weekend? Ring our 24/7 roster or WhatsApp any hour, and missed calls are always called back. You are told when we can be at your address before anyone sets off.
One day swaps
Pump swaps usually take one day, and we take the old pump away and dispose of it.
In house electrician
Hard wired pumps, new circuits and three phase pumps are wired by our own electrician on the same visit.
Surge and flood damage tested
Surge or flood damage? We test the gear and tell you what failed and why, so you can pass it on to your insurer.
Fault found before a pump is sold
We are Master Plumbers members, and we test first and put the price in writing, GST shown.
Prep & Photos
Photos and details that help
Snap the pump label, the vessel or controller, the filters and the whole layout. Tell us if it plugs in or is wired in and, if you know it, single or three phase. Also say whether your water comes from a tank, a bore, a spring or the council.
Rough distances help too: tank to pump, and pump to the house. Mention what heats your water and whether the pump has been making new noises.
Wiring & Licensing
Who is allowed to wire a pump
Paid electrical work in New Zealand needs a registered worker with a current practising licence. The homeowner exemption is narrow: unpaid work by owners on the home they live in. It never covers tradespeople, landlords or tenants.
Our electrician does the pump wiring, booked with your job: unhooking and reconnecting a hard wired pump, three phase pumps, new circuits, wiring faults and switchboard work, with that cost shown on your quote.
Process & Steps
From no water to running again
01
Call or send photos
A quick phone chat sometimes gets a pump going again with a reset, no visit needed.
02
We test the whole system
Power, water level, suction side, vessel, switch and pump, with pressure readings as we go.
03
Repair, replace or loan
You get the options and costs in writing. Pump going to the workshop? A loan unit keeps the water on.
04
Back in and checked
We fit the repaired or new pump, set the vessel and switch, and run every tap before we leave.
Costs & Quotes
How pump work is priced
Every pump job is quoted, because a reset switch and a new bore pump are worlds apart. You hear the cost of the first visit, GST included, before we book you in.
A replacement quote spells out the pump model, vessel, controller, fittings, taking away the old pump, any electrician time and the loan pump charge if you need one. The price of a pump on a shelf is not the price of it working at your place, so compare whole quotes.
Travel, access, whether the old pump is worth fixing and the time you call all move the number. At night or over a weekend, the after hours rate is quoted over the phone before anyone heads your way.
If we find a leak, a cracked suction pipe or a wiring fault once we start, we stop and price it before going further.
Request a quoteLocal & Regional
Pumps across Whangarei and Northland
WDC's council supply reaches around four in five people in the district. The rest, mostly rural and coastal homes, rely on their own tank or bore, and the pump is all that stands between them and dry taps.
Mangawhai and most of rural Kaipara run on tank water too. Around Kerikeri many lifestyle blocks also have an irrigation supply that is not safe to drink, and it must never be joined to the house plumbing.
In past droughts Northland Regional Council has warned that bore levels near the coast can drop and the water can go salty. For a critical supply problem, NRC's number is 0800 002 004.
Our vans leave from Whangarei and cover all of Northland: Kaitaia, Kerikeri, the Bay of Islands, Dargaville and Mangawhai. Travel beyond the Whangarei district goes in the quote before we set off, and from the far end of the region you get a straight answer on timing.
WDC private water supply adviceCustomers & Properties
Lifestyle blocks, baches, rentals and more
Rural and lifestyle homes
When the pump stops, so does the house, the stock trough and sometimes a second dwelling.
Holiday homes
Pumps love to fail with nobody home. We meet your caretaker on site, fix it and leave it going.
Landlords and tenants
A rental with no water is urgent. Tenants, tell your landlord or manager first; we arrange access and approval with whoever pays.
Body corporates and businesses
Booster sets serving several units or a workplace. We plan any shutdown with whoever can sign it off.
Related & Similar
Related services
A pump call out often turns up one of these.
Low Water Pressure
Weak taps on town water, valves and cylinders.
Rainwater Harvesting
Tanks, gutter feeds, first flush and top ups.
Water Filtration
Filters and UV for tank and bore water.
Backflow Testing & Prevention
Keeping tank or bore water out of the council main.
Water Mains
Buried pipe from the tank or meter to the house.
Leak Detection
Tracking the leak that keeps your pump starting.
Emergency Plumbing
Urgent water problems at any hour.
Pump Installs
New tank, bore and pressure pumps sized and fitted.
Questions & Answers
Water pump questions
How much does a new water pump cost?
It depends on the pump and the setup, and you get a written price once we know what is wrong. A switch or vessel is far less than a new pump, and a bore pump costs more again because it has to be lifted out.
Why is my pump running but no water comes out?
It has most likely lost prime or is sucking air. A cracked suction pipe, a leaking foot valve, a closed valve on the suction side or a tank that has run too low will all do it.
My pump keeps cutting in and out. What is wrong?
Usually a flat pressure vessel, or water slipping away somewhere. Leaking taps, a toilet float valve that never quite shuts and a non return or foot valve that has worn are the regulars. We sort the pump side first, then go hunting for the leak.
My pump died on the weekend. Will you come?
Yes. A house with no water gets a call out any day of the week, at any hour. We fix it on the spot when parts allow; otherwise a loan unit goes in so you are not left waiting.
The power came back but my pump did not. What now?
Check the whole house has power, not just some circuits. If the supply is still off, that is the lines company's job, and Northpower asks you to call them before an electrician. Power fine but the pump stays dead or keeps tripping? Ring us to test it, and see our no water page for the other checks.
Does my water pump work when the power is out?
No. No power means no pump, and a tank full to the brim will not reach the taps on its own. Civil Defence advises storing a minimum of three litres a person each day for three days. Water sitting in your hot water cylinder can be used too.
Can you lend me a pump while mine is fixed?
Yes. When a pump needs bench work or parts, a loan unit goes in and the taps stay on.
Should I repair or replace my water pump?
Repair if the motor and pump body are sound and the fault is a switch, vessel, seal or controller. Replace if it is worn out, too small for the house or parts have dried up.
Is a plumber allowed to unhook a wired in pump?
Only if they also hold an electrical registration endorsed for that work. On our jobs, our electrician does it, booked with the job. A pump that plugs into a socket needs neither.
Do I need a building consent for a new pump?
Usually not, if the new pump matches the old one and goes in the same place. The Building Act's Schedule 1 lets you replace sanitary plumbing with a comparable product in the same position without consent. Moving to a different system or a new location can change that, and we tell you before quoting.
Can I fit a booster pump to the council supply?
Not straight onto the main. In Whangarei the pump has to draw from its own tank, filled over an air gap, with backflow protection at the boundary. Kaipara bans a direct pump connection outright.
How often should a tank and bore system be serviced?
Every three months, and after any storm, check the tank's inlet and outlet screens and empty the strainer. Check the tank's condition every year and its sludge level every two years, and get it cleaned when it is dirty. Clean the bore intake and screens once a year, and book a professional bore service every 5 to 8 years. Our service visit adds the pump, vessel and filters.
My tank is empty. Can I get water delivered?
Yes, from a water carrier. Use one on the Taumata Arowai register and ask for written confirmation of where the water came from. In a dry summer carriers get booked up, so order before the tank hits the bottom.
Will you write a report for my insurer after a surge?
Yes. We test the pump and controller, note what failed and the likely cause, and put it in writing for your claim. Keep the old parts until your insurer says they are done with them.
My bore pump is sucking air in a dry spell. Why?
The water level in the bore may have dropped near or below the pump. Coastal Northland bores can also turn salty in a drought. We can check the pump depth and controls; yield questions go to a driller or hydrogeologist.
Get your water running again
Send a photo of the pump and tell us where your water comes from. We will test it, give you the options in writing and keep the taps going while we work.